{"id":1049,"date":"2026-06-03T20:02:46","date_gmt":"2026-06-03T12:02:46","guid":{"rendered":"https:\/\/www.kcvents.com\/?post_type=product&#038;p=1049"},"modified":"2026-09-07T19:54:03","modified_gmt":"2026-09-07T11:54:03","slug":"ec-energy-recovery-ventilator","status":"publish","type":"product","link":"https:\/\/www.kcvents.com\/ar\/products\/ec-energy-recovery-ventilator\/","title":{"rendered":"EC Energy Recovery Ventilator"},"content":{"rendered":"<div class=\"kc-ptc-wrap\">\n<section id=\"overview\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">System Overview<\/span><\/h2>\n<div>\n<p>EC Energy Recovery Ventilator delivers balanced whole-house ventilation for residential and light commercial projects: it supplies fresh outdoor air while exhausting stale indoor air, and the heat recovery core transfers energy between the two streams to reduce heating and cooling loss.<\/p>\n<p>The EC motor provides variable-speed control, which keeps operation efficient and quieter across partial-load conditions. With models ranging from 90~180 m\u00b3\/h up to 480~800 m\u00b3\/h airflow, the series covers compact homes through larger whole-house and project installations.<\/p>\n<\/div>\n<\/section>\n<section id=\"features-benefits\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Core Engineering Features<\/span><\/h2>\n<p class=\"kc-sec-lead\">Designed for dependable whole-house recovery ventilation with efficient motor control, recoverable thermal energy and simple installation.<\/p>\n<div class=\"kc-grid-3\">\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag blue\">EC MOTOR<\/div>\n<h3 class=\"kc-feature-title\">Variable-speed control<\/h3>\n<p class=\"kc-feature-desc\">EC motor with variable speed adjusts airflow to demand, lowering power use and noise during partial-load operation.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag amber\">HEAT RECOVERY<\/div>\n<h3 class=\"kc-feature-title\">Recovery core<\/h3>\n<p class=\"kc-feature-desc\">Heat exchange rates up to 82% in heating mode help keep indoor comfort stable while reducing energy loss.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag green\">AIR QUALITY<\/div>\n<h3 class=\"kc-feature-title\">Washable filter system<\/h3>\n<p class=\"kc-feature-desc\">Washable or replaceable filters block dust and pollutants while the unit runs continuous fresh-air supply.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag purple\">QUIET RUNNING<\/div>\n<h3 class=\"kc-feature-title\">Low-noise operation<\/h3>\n<p class=\"kc-feature-desc\">31\u201341 dB noise range across the model line supports residential and low-noise project environments.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag teal\">FLEXIBLE MOUNTING<\/div>\n<h3 class=\"kc-feature-title\">Wall or ceiling mount<\/h3>\n<p class=\"kc-feature-desc\">Compact unit size with straightforward installation and wiring for retrofit and new-build projects.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag gray\">MODEL RANGE<\/div>\n<h3 class=\"kc-feature-title\">90\u2013800 m\u00b3\/h coverage<\/h3>\n<p class=\"kc-feature-desc\">Six models from CHQR-180EC to CHQR-800EC with \u00d8100\u2013\u00d8200 mm duct options for different project layouts.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"technical-specifications\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Technical Specifications<\/span><\/h2>\n<div style=\"margin-bottom: 24px\">\n<h3 class=\"kc-spec-heading\"><i class=\"fa-solid fa-sliders\"><\/i> Dimension Table (unit: mm)<\/h3>\n<div class=\"kc-table-wrap\">\n<table class=\"kc-table\">\n<thead>\n<tr>\n<th>Model<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<th>C<\/th>\n<th>D<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>H<\/th>\n<th>I<\/th>\n<th>J<\/th>\n<th>K<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CHQR &#8211; 180EC<\/td>\n<td>856<\/td>\n<td>750<\/td>\n<td>95<\/td>\n<td>12<\/td>\n<td>305<\/td>\n<td>536<\/td>\n<td>597<\/td>\n<td>186<\/td>\n<td>305<\/td>\n<td>536<\/td>\n<td>582<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 350EC<\/td>\n<td>894<\/td>\n<td>780<\/td>\n<td>145<\/td>\n<td>12<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<td>208<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 450EC<\/td>\n<td>984<\/td>\n<td>780<\/td>\n<td>145<\/td>\n<td>21<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<td>208<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 550EC<\/td>\n<td>894<\/td>\n<td>780<\/td>\n<td>145<\/td>\n<td>12<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<td>208<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 600EC<\/td>\n<td>1096<\/td>\n<td>985<\/td>\n<td>195<\/td>\n<td>12<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<td>272<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 800EC<\/td>\n<td>1096<\/td>\n<td>985<\/td>\n<td>195<\/td>\n<td>12<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<td>272<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div style=\"margin-bottom: 24px\">\n<h3 class=\"kc-spec-heading\"><i class=\"fa-solid fa-sliders\"><\/i> Parameter Table<\/h3>\n<div class=\"kc-table-wrap\">\n<table class=\"kc-table\">\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Voltage (V\/Hz)<\/th>\n<th>Airflow (m\u00b3\/h)<\/th>\n<th>Static Pressure (Pa)<\/th>\n<th>Power (W)<\/th>\n<th>Heat Exchange Rate (%) [Cooling\/Heating]<\/th>\n<th>Enthalpy Exchange Rate (%) [Cooling\/Heating]<\/th>\n<th>Noise (dB)<\/th>\n<th>Duct Size (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CHQR &#8211; 180EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>90~180<\/td>\n<td>115<\/td>\n<td>10~46<\/td>\n<td>60 \/ 79<\/td>\n<td>60 \/ 71<\/td>\n<td>31<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 350EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>190~350<\/td>\n<td>122<\/td>\n<td>13~56<\/td>\n<td>61 \/ 79<\/td>\n<td>60 \/ 69<\/td>\n<td>33<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 450EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>220~450<\/td>\n<td>146<\/td>\n<td>15~88<\/td>\n<td>60 \/ 78<\/td>\n<td>60 \/ 70<\/td>\n<td>35<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 550EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>225~550<\/td>\n<td>158<\/td>\n<td>15~110<\/td>\n<td>58 \/ 80<\/td>\n<td>58 \/ 68<\/td>\n<td>38<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 600EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>385~650<\/td>\n<td>197<\/td>\n<td>33~190<\/td>\n<td>58 \/ 82<\/td>\n<td>58 \/ 68<\/td>\n<td>40<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 800EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>480~800<\/td>\n<td>239<\/td>\n<td>45~260<\/td>\n<td>58 \/ 82<\/td>\n<td>58 \/ 67<\/td>\n<td>41<\/td>\n<td>200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"performance-curves\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Performance Curves<\/span><\/h2>\n<div class=\"kc-panel\">\n<p class=\"kc-sec-lead\">EC series airflow and static-pressure performance can be reviewed visually before model selection.<\/p>\n<div style=\"text-align: center\">\n<img decoding=\"async\" style=\"max-width: 100%;height: auto;border-radius: 6px\" src=\"\/wp-content\/uploads\/2026\/08\/kcqr-ec-xiao.webp\" alt=\"EC Energy Recovery Ventilator performance curves\" \/>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"applications\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Target Applications<\/span><\/h2>\n<p class=\"kc-sec-lead\">Whole-house recovery ventilation for spaces that need continuous fresh air without wasting thermal energy.<\/p>\n<div class=\"kc-apps-wrap\">\n<div class=\"kc-grid-3\">\n<div class=\"kc-app-card app-residential\">\n<div class=\"kc-app-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"52\" height=\"52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M3 11l9-8 9 8\"><\/path><path d=\"M5 10v11h14V10\"><\/path><path d=\"M9 21v-6h6v6\"><\/path><path d=\"M9 11h1\"><\/path><path d=\"M14 11h1\"><\/path><\/svg><\/div>\n<h3 class=\"kc-app-title\">Homes &amp; Apartments<\/h3>\n<p class=\"kc-app-desc\">Balanced fresh-air delivery for houses and apartments that want stable indoor comfort with less energy loss.<\/p>\n<\/div>\n<div class=\"kc-app-card app-commercial\">\n<div class=\"kc-app-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"52\" height=\"52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M4 10h16\"><\/path><path d=\"M5 10l1-5h12l1 5\"><\/path><path d=\"M6 10v9h12v-9\"><\/path><path d=\"M9 19v-5h6v5\"><\/path><path d=\"M6 10c0 1.1.9 2 2 2s2-.9 2-2\"><\/path><path d=\"M10 10c0 1.1.9 2 2 2s2-.9 2-2\"><\/path><path d=\"M14 10c0 1.1.9 2 2 2s2-.9 2-2\"><\/path><\/svg><\/div>\n<h3 class=\"kc-app-title\">Light Commercial<\/h3>\n<p class=\"kc-app-desc\">Offices, clinics, classrooms and project spaces that need dependable recovery ventilation without a large ducted system.<\/p>\n<\/div>\n<div class=\"kc-app-card app-industrial\">\n<div class=\"kc-app-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"52\" height=\"52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M3 21h18\"><\/path><path d=\"M5 21V9l5 3V9l5 3V5h4v16\"><\/path><path d=\"M9 21v-4h2v4\"><\/path><path d=\"M15 21v-4h2v4\"><\/path><path d=\"M7 14h1\"><\/path><path d=\"M12 14h1\"><\/path><path d=\"M17 14h1\"><\/path><\/svg><\/div>\n<h3 class=\"kc-app-title\">Retrofit &amp; Projects<\/h3>\n<p class=\"kc-app-desc\">Wall- or ceiling-mount units suit renovation projects and repeat B2B supply programs with configurable model selection.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"quality-assurance\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Quality Assurance<\/span><\/h2>\n<p class=\"kc-sec-lead\">Project supply is checked against structure, airflow and noise targets before release.<\/p>\n<div class=\"kc-panel\">\n<div class=\"kc-grid-2\">\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">Heat-Exchanger Sealing<\/h3>\n<p class=\"kc-feature-desc\">Core sealing and airflow path consistency checked against published project specifications.<\/p>\n<\/div>\n<\/div>\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">EC Motor Performance<\/h3>\n<p class=\"kc-feature-desc\">Motor load and efficiency reviewed for stable long-hour operation.<\/p>\n<\/div>\n<\/div>\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">Airflow Balance<\/h3>\n<p class=\"kc-feature-desc\">Supply and exhaust airflow balance verified for whole-house deployment.<\/p>\n<\/div>\n<\/div>\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">Noise Verification<\/h3>\n<p class=\"kc-feature-desc\">Published dB targets checked against factory data before release.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"certifications\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Certifications &amp; Compliance<\/span><\/h2>\n<div class=\"kc-panel\">\n<div class=\"kcvents-cert-list\" style=\"display:flex;flex-wrap:wrap;gap:10px\"><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">ISO 9001<\/span><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">.WeDrive<\/span><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">ERV IEC TEST REPORT<\/span><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">KCQR ERP 150 350 500<\/span><\/div>\n<\/div>\n<\/section>\n<section id=\"oem-odm-warranty\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">OEM\/ODM &amp; Project Support<\/span><\/h2>\n<div class=\"kc-panel\">\n<p>KCVENTS supports OEM\/ODM services, private-label supply, regional plug and voltage options, catalog documentation and warranty support for qualified project and distributor orders.<\/p>\n<p>Warranty and service terms are confirmed according to the final order agreement.<\/p>\n<\/div>\n<\/section>\n<section id=\"faq\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">FAQ<\/span><\/h2>\n<div class=\"kc-panel\">\n<div class=\"kc-faq-item\">\n<details>\n<summary>What models are available in the EC series?<\/summary>\n<p>The series covers CHQR-180EC, CHQR-350EC, CHQR-450EC, CHQR-550EC, CHQR-600EC and CHQR-800EC, with airflow from 90~180 m\u00b3\/h up to 480~800 m\u00b3\/h.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>What is the maximum heat recovery efficiency?<\/summary>\n<p>Heat exchange rate reaches up to 82% in heating mode and 61% in cooling mode across the model range; duct size options are \u00d8100 mm, \u00d8150 mm and \u00d8200 mm.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>What voltage does the unit support?<\/summary>\n<p>All models accept 180V~240V at 50\/60 Hz, which covers most residential and light commercial mains supplies.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>Can the filters be cleaned?<\/summary>\n<p>Yes. The washable or replaceable filter system is designed for routine maintenance without special tools.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>Does KCVENTS support OEM\/ODM orders for this product?<\/summary>\n<p>Yes. OEM branding, control options, documentation and regional voltage configurations can be reviewed for qualified project and distributor orders.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This whole-house EC energy recovery ventilator delivers balanced fresh air, lower thermal loss and efficient EC motor control for residential and light commercial projects.<\/p>\n<ul class=\"kcvents-short-points\">\n<li>\u0645\u062d\u0631\u0643 EC \u0645\u0639 \u062a\u062d\u0643\u0645 \u0645\u062a\u063a\u064a\u0631 \u0627\u0644\u0633\u0631\u0639\u0629 \u0644\u062a\u0634\u063a\u064a\u0644 \u0647\u0627\u062f\u0626 \u0648\u0639\u0627\u0644\u064a \u0627\u0644\u0643\u0641\u0627\u0621\u0629<\/li>\n<li>\u0642\u0644\u0628 \u0627\u0633\u062a\u0631\u062f\u0627\u062f \u062d\u0631\u0627\u0631\u064a \u0628\u0643\u0641\u0627\u0621\u0629 \u062d\u0631\u0627\u0631\u064a\u0629 \u062a\u0635\u0644 \u0625\u0644\u0649 82%<\/li>\n<li>\u0625\u0645\u062f\u0627\u062f \u0645\u0633\u062a\u0645\u0631 \u0628\u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0646\u0642\u064a \u0645\u0639 \u0625\u0645\u062f\u0627\u062f \u0648\u0637\u0631\u062f \u0645\u062a\u0648\u0627\u0632\u0646\u064a\u0646<\/li>\n<li>\u0641\u0644\u0627\u062a\u0631 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u063a\u0633\u0644 \u0623\u0648 \u0627\u0644\u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0644\u062d\u062c\u0628 \u0627\u0644\u063a\u0628\u0627\u0631 \u0648\u0627\u0644\u0645\u0644\u0648\u062b\u0627\u062a<\/li>\n<li>\u062a\u0635\u0645\u064a\u0645 \u0645\u062f\u0645\u062c \u0644\u0644\u062a\u0631\u0643\u064a\u0628 \u0639\u0644\u0649 \u0627\u0644\u062d\u0627\u0626\u0637 \u0623\u0648 \u0627\u0644\u0633\u0642\u0641 \u0644\u062a\u0633\u0647\u064a\u0644 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/li>\n<\/ul>","protected":false},"featured_media":2426,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","iawp_total_views":21},"product_brand":[],"product_cat":[23],"product_tag":[],"class_list":["post-1049","product","type-product","status-publish","has-post-thumbnail","product_cat-whole-house-erv-hrv-systems","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/product\/1049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/comments?post=1049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/media\/2426"}],"wp:attachment":[{"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/media?parent=1049"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1049"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1049"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcvents.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}