{"id":4718,"date":"2026-11-20T20:33:01","date_gmt":"2026-11-20T12:33:01","guid":{"rendered":"https:\/\/www.kcvents.com\/duct-size-calculator\/"},"modified":"2026-11-20T21:16:52","modified_gmt":"2026-11-20T13:16:52","slug":"duct-size-calculator","status":"publish","type":"page","link":"https:\/\/www.kcvents.com\/de\/duct-size-calculator\/","title":{"rendered":"Ductulator: Duct Size Calculator"},"content":{"rendered":"\n<style>\n#main .kc-duct{--pine:#1E3A2F;--pine-d:#12241D;--gold:#C09553;--ink:#192024;--ink2:#4F5B61;--line:rgba(25,32,36,.12);--soft:#F4F6F5;--warn:#9A5B00;--warn-bg:#FFF6E5;color:var(--ink);font-size:17px;line-height:1.65;max-width:1080px;margin:0 auto;padding:8px 0 40px}\n#main .kc-duct *{box-sizing:border-box}\n#main .kc-duct h1{font-size:clamp(28px,4vw,40px);line-height:1.2;margin:8px 0 12px;color:var(--pine-d)}\n#main .kc-duct h2{font-size:clamp(22px,3vw,28px);line-height:1.3;margin:44px 0 12px;color:var(--pine-d)}\n#main .kc-duct h3{font-size:19px;margin:24px 0 8px;color:var(--pine-d)}\n#main .kc-duct p,#main .kc-duct li{color:var(--ink)}\n#main .kc-duct .lead{font-size:18px;color:var(--ink2);max-width:860px}\n#main .kc-duct a{color:var(--pine);text-decoration:underline;text-underline-offset:2px}\n#main .kc-duct .app{border:1px solid var(--line);border-radius:16px;background:#fff;box-shadow:0 6px 24px rgba(0,0,0,.05);margin:24px 0;overflow:hidden}\n#main .kc-duct .bar{display:flex;flex-wrap:wrap;gap:10px;justify-content:space-between;align-items:center;padding:14px 18px;background:var(--pine);color:#fff}\n#main .kc-duct .seg{display:inline-flex;background:rgba(255,255,255,.12);border-radius:999px;padding:3px}\n#main .kc-duct .seg button{border:0;background:transparent;color:#fff;font:inherit;font-size:15px;padding:6px 14px;border-radius:999px;cursor:pointer}\n#main .kc-duct .seg button[aria-pressed=\"true\"]{background:#fff;color:var(--pine-d);font-weight:600}\n#main .kc-duct .grid{display:grid;grid-template-columns:minmax(0,5fr) minmax(0,7fr)}\n#main .kc-duct .in{padding:20px 18px;border-right:1px solid var(--line);background:var(--soft)}\n#main .kc-duct .out{padding:20px 18px}\n#main .kc-duct label.f{display:block;font-size:14px;font-weight:600;color:var(--ink2);margin:14px 0 6px}\n#main .kc-duct .row{display:flex;gap:8px;align-items:center}\n#main .kc-duct input[type=number],#main .kc-duct select{width:100%;font:inherit;font-size:17px;padding:9px 11px;border:1px solid var(--line);border-radius:10px;background:#fff;color:var(--ink);min-width:0}\n#main .kc-duct .u{font-size:14px;color:var(--ink2);white-space:nowrap;min-width:64px}\n#main .kc-duct .radio{display:flex;gap:16px;flex-wrap:wrap;font-size:16px}\n#main .kc-duct .radio label{display:flex;gap:6px;align-items:center;cursor:pointer}\n#main .kc-duct .hide{display:none!important}\n#main .kc-duct .big{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px}\n#main .kc-duct .card{border:1px solid var(--line);border-radius:12px;padding:12px 14px}\n#main .kc-duct .card.hl{border-color:var(--pine);background:#EDF3F0}\n#main .kc-duct .k{font-size:13px;color:var(--ink2);text-transform:uppercase;letter-spacing:.04em}\n#main .kc-duct .v{font-size:26px;font-weight:700;color:var(--pine-d);line-height:1.25}\n#main .kc-duct .s{font-size:14px;color:var(--ink2)}\n#main .kc-duct .mini{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:8px;margin-top:8px}\n#main .kc-duct .mini div{font-size:14px}\n#main .kc-duct .mini b{display:block;font-size:17px;color:var(--ink)}\n#main .kc-duct .note{border-left:4px solid var(--warn);background:var(--warn-bg);color:#5C3A00;padding:10px 12px;border-radius:8px;font-size:15px;margin-top:12px}\n#main .kc-duct .tw{overflow-x:auto;-webkit-overflow-scrolling:touch;margin-top:8px}\n#main .kc-duct table{border-collapse:collapse;width:100%;font-size:15px;min-width:460px}\n#main .kc-duct th,#main .kc-duct td{border-bottom:1px solid var(--line);padding:8px 10px;text-align:left;vertical-align:top}\n#main .kc-duct thead th{background:var(--soft);font-size:13px;text-transform:uppercase;letter-spacing:.03em;color:var(--ink2)}\n#main .kc-duct .fans{margin-top:16px;border-top:1px dashed var(--line);padding-top:12px}\n#main .kc-duct .fans ul{margin:6px 0 0 18px;padding:0}\n#main .kc-duct .formula{font-family:ui-monospace,Consolas,monospace;background:var(--soft);border-radius:8px;padding:10px 12px;overflow-x:auto;font-size:15px}\n#main .kc-duct blockquote{margin:12px 0;padding:8px 14px;border-left:4px solid var(--gold);background:#FBF7F0;color:var(--ink)}\n#main .kc-duct cite{display:block;font-style:normal;font-size:14px;color:var(--ink2);margin-top:4px}\n#main .kc-duct details{border:1px solid var(--line);border-radius:10px;padding:10px 14px;margin:10px 0;background:#fff}\n#main .kc-duct summary{cursor:pointer;font-weight:600;color:var(--pine-d)}\n#main .kc-duct .cta{margin:36px 0 0;padding:20px;border-radius:14px;background:var(--pine);color:#fff}\n#main .kc-duct .cta p{color:#fff}\n#main .kc-duct .cta a.btn{display:inline-block;background:var(--gold);color:#1b1b1b;text-decoration:none;font-weight:700;padding:10px 18px;border-radius:999px;margin-top:6px}\n#main .kc-duct .src li{font-size:15px}\n@media (max-width:820px){#main .kc-duct .grid{grid-template-columns:minmax(0,1fr)}#main .kc-duct .u{white-space:normal;min-width:0;max-width:40%}#main .kc-duct .in{border-right:0;border-bottom:1px solid var(--line)}#main .kc-duct .mini{grid-template-columns:repeat(2,minmax(0,1fr))}}\n@media (max-width:480px){#main .kc-duct .big{grid-template-columns:1fr}#main .kc-duct .v{font-size:23px}}\n<\/style>\n\n<div class=\"kc-duct\">\n<h1>Ductulator: Duct Size Calculator for Round and Rectangular Ducts<\/h1>\n<p class=\"lead\">Enter the airflow and either a design friction rate or a maximum air velocity. This ductulator returns the round duct diameter, the next common size, rectangular ducts with the same pressure loss, and the velocity and friction you will actually get at each size. It works in CFM and inches or in m\u00b3\/h and millimetres.<\/p>\n\n<div class=\"app\" id=\"kcd-app\">\n  <div class=\"bar\">\n    <div class=\"seg\" role=\"group\" aria-label=\"Units\">\n      <button type=\"button\" data-sys=\"inch\" aria-pressed=\"true\">CFM \u00b7 inches<\/button>\n      <button type=\"button\" data-sys=\"metric\" aria-pressed=\"false\">m\u00b3\/h \u00b7 mm<\/button>\n    <\/div>\n    <div class=\"seg\" role=\"group\" aria-label=\"Mode\">\n      <button type=\"button\" data-mode=\"size\" aria-pressed=\"true\">Size a duct<\/button>\n      <button type=\"button\" data-mode=\"check\" aria-pressed=\"false\">Check a duct<\/button>\n    <\/div>\n  <\/div>\n  <div class=\"grid\">\n    <div class=\"in\">\n      <label class=\"f\" for=\"kcd-q\">Airflow<\/label>\n      <div class=\"row\"><input id=\"kcd-q\" type=\"number\" min=\"1\" step=\"any\" value=\"400\"><span class=\"u\"><span data-imp>CFM<\/span><select id=\"kcd-qu\" data-met class=\"hide\" aria-label=\"Airflow unit\" style=\"width:auto;padding:6px 8px;font-size:15px\"><option value=\"m3h\">m\u00b3\/h<\/option><option value=\"ls\">L\/s<\/option><\/select><\/span><\/div>\n\n      <div data-for=\"size\">\n        <label class=\"f\">Size by<\/label>\n        <div class=\"radio\">\n          <label><input type=\"radio\" name=\"kcd-m\" value=\"friction\" checked> Friction rate<\/label>\n          <label><input type=\"radio\" name=\"kcd-m\" value=\"velocity\"> Maximum velocity<\/label>\n        <\/div>\n        <div id=\"kcd-fbox\">\n          <label class=\"f\" for=\"kcd-fr\">Design friction rate<\/label>\n          <div class=\"row\"><input id=\"kcd-fr\" type=\"number\" min=\"0.001\" step=\"any\" value=\"0.1\"><span class=\"u\"><span data-imp>in. w.g. \/ 100 ft<\/span><span data-met class=\"hide\">Pa\/m<\/span><\/span><\/div>\n        <\/div>\n        <div id=\"kcd-vbox\" class=\"hide\">\n          <label class=\"f\" for=\"kcd-v\">Maximum air velocity<\/label>\n          <div class=\"row\"><input id=\"kcd-v\" type=\"number\" min=\"0.1\" step=\"any\" value=\"900\"><span class=\"u\"><span data-imp>fpm<\/span><span data-met class=\"hide\">m\/s<\/span><\/span><\/div>\n        <\/div>\n      <\/div>\n\n      <div data-for=\"check\" class=\"hide\">\n        <label class=\"f\">Duct shape<\/label>\n        <div class=\"radio\">\n          <label><input type=\"radio\" name=\"kcd-shape\" value=\"round\" checked> Round<\/label>\n          <label><input type=\"radio\" name=\"kcd-shape\" value=\"rect\"> Rectangular<\/label>\n        <\/div>\n        <div id=\"kcd-dbox\">\n          <label class=\"f\" for=\"kcd-d\">Diameter<\/label>\n          <div class=\"row\"><input id=\"kcd-d\" type=\"number\" min=\"1\" step=\"any\" value=\"10\"><span class=\"u\"><span data-imp>in<\/span><span data-met class=\"hide\">mm<\/span><\/span><\/div>\n        <\/div>\n        <div id=\"kcd-rbox\" class=\"hide\">\n          <label class=\"f\" for=\"kcd-w\">Width \u00d7 height<\/label>\n          <div class=\"row\"><input id=\"kcd-w\" type=\"number\" min=\"1\" step=\"any\" value=\"14\" aria-label=\"Width\"><span>\u00d7<\/span><input id=\"kcd-h\" type=\"number\" min=\"1\" step=\"any\" value=\"8\" aria-label=\"Height\"><span class=\"u\"><span data-imp>in<\/span><span data-met class=\"hide\">mm<\/span><\/span><\/div>\n        <\/div>\n        <label class=\"f\" for=\"kcd-len\">Length of straight duct<\/label>\n        <div class=\"row\"><input id=\"kcd-len\" type=\"number\" min=\"0\" step=\"any\" value=\"50\"><span class=\"u\"><span data-imp>ft<\/span><span data-met class=\"hide\">m<\/span><\/span><\/div>\n      <\/div>\n\n      <label class=\"f\" for=\"kcd-mat\">Duct material<\/label>\n      <select id=\"kcd-mat\">\n        <option value=\"pvc\">PVC or aluminium (very smooth)<\/option>\n        <option value=\"galvanized\" selected>Galvanized or stainless steel<\/option>\n        <option value=\"lined\">Lined duct (PE or glass fibre)<\/option>\n        <option value=\"flexible\">Flexible duct, pulled tight<\/option>\n      <\/select>\n      <p class=\"s\" style=\"margin-top:12px\">Air at 20 \u00b0C (68 \u00b0F) at sea level. Straight duct only: add fittings separately.<\/p>\n    <\/div>\n\n    <div class=\"out\" aria-live=\"polite\">\n      <div data-for=\"size\">\n        <div class=\"big\">\n          <div class=\"card\"><div class=\"k\">Exact round diameter<\/div><div class=\"v\" id=\"kcd-exact\">\u2013<\/div><div class=\"s\" id=\"kcd-exact2\"><\/div><\/div>\n          <div class=\"card hl\"><div class=\"k\">Next common size<\/div><div class=\"v\" id=\"kcd-next\">\u2013<\/div><div class=\"s\" id=\"kcd-next2\"><\/div><\/div>\n        <\/div>\n        <div class=\"mini\">\n          <div>Velocity at this size<b id=\"kcd-nv\">\u2013<\/b><\/div>\n          <div>Friction at this size<b id=\"kcd-nf\">\u2013<\/b><\/div>\n          <div>Velocity pressure<b id=\"kcd-np\">\u2013<\/b><\/div>\n        <\/div>\n        <div class=\"note hide\" id=\"kcd-warn-sup\">The velocity is above 900 fpm (4.6 m\/s), the Manual D maximum for residential supply ducts. Choose a larger size if this is a home supply run.<\/div>\n        <div class=\"note hide\" id=\"kcd-warn-ret\">The velocity is above 700 fpm (3.6 m\/s), the Manual D maximum for residential return ducts.<\/div>\n        <div class=\"note hide\" id=\"kcd-warn-big\">This airflow is beyond the common sizes listed here. Use the rectangular options or split the airflow.<\/div>\n        <h3>Rectangular ducts with the same friction<\/h3>\n        <div class=\"tw\"><table><thead><tr><th>Width \u00d7 height<\/th><th>Aspect ratio<\/th><th>Equivalent round<\/th><th>Velocity<\/th><th>Friction rate<\/th><\/tr><\/thead><tbody id=\"kcd-rect\"><\/tbody><\/table><\/div>\n        <p class=\"s\">Widths are rounded up to the next 2 in (50 mm), so each rectangle has a slightly lower friction rate than the target. Aspect ratios above 4:1 are left out.<\/p>\n        <div class=\"fans\" id=\"kcd-fans\">\n          <div class=\"k\">KCVENTS inline duct fans for this connection size<\/div>\n          <ul id=\"kcd-fanlist\"><\/ul>\n          <p class=\"s hide\" id=\"kcd-fanbig\">Above 315 mm (12 in), duct fans are chosen on the fan curve: see the <a href=\"\/product-category\/ktj-cabinet-fan\/\">cabinet fans<\/a> or <a href=\"\/contact\/\">send us your airflow and pressure<\/a>.<\/p>\n        <\/div>\n      <\/div>\n\n      <div data-for=\"check\" class=\"hide\">\n        <div class=\"big\">\n          <div class=\"card hl\"><div class=\"k\">Air velocity<\/div><div class=\"v\" id=\"kcd-cv\">\u2013<\/div><div class=\"s\" id=\"kcd-cv2\"><\/div><\/div>\n          <div class=\"card\"><div class=\"k\">Friction rate<\/div><div class=\"v\" id=\"kcd-cf\">\u2013<\/div><div class=\"s\" id=\"kcd-cf2\"><\/div><\/div>\n        <\/div>\n        <div class=\"mini\">\n          <div>Loss over this length<b id=\"kcd-cl\">\u2013<\/b><\/div>\n          <div>Equivalent round<b id=\"kcd-ce\">\u2013<\/b><\/div>\n          <div>Velocity pressure<b id=\"kcd-cp\">\u2013<\/b><\/div>\n        <\/div>\n        <div class=\"note hide\" id=\"kcd-cwarn-sup\">The velocity is above 900 fpm (4.6 m\/s), the Manual D maximum for residential supply ducts.<\/div>\n        <div class=\"note hide\" id=\"kcd-cwarn-ret\">The velocity is above 700 fpm (3.6 m\/s), the Manual D maximum for residential return ducts.<\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n<\/div>\n\n<h2>How to size a duct in three steps<\/h2>\n<ol>\n  <li><strong>Find the airflow for each run.<\/strong> Start from the room or equipment airflow. If you only know the room, the <a href=\"\/ventilation-cfm-calculator\/\">ventilation CFM calculator<\/a> turns room size and air changes per hour into CFM and m\u00b3\/h.<\/li>\n  <li><strong>Set a friction rate, or a velocity limit.<\/strong> The friction rate is how much pressure you can afford to lose per 100 ft (or per metre) of duct. It comes from the fan&#8217;s available pressure and the length of the longest run (next section).<\/li>\n  <li><strong>Read the diameter, then check the velocity.<\/strong> Round up to a size you can buy. If the velocity at that size is too high for the space, go one size up. Ducts that are too fast are noisy, and ducts that are too small starve the rooms at the end of the run.<\/li>\n<\/ol>\n\n<h3>Worked example: 400 CFM<\/h3>\n<p>With a design friction rate of 0.073 in. w.g. per 100 ft, the calculator gives an exact diameter of 10.35 in. Energy Vanguard ran the same 400 CFM at 0.073 through the ASHRAE duct calculator wheel and needed &#8220;a round metal duct that\u2019s slightly larger than 10\u2033&#8221;. In a 10 in duct the air moves at 733 fpm with 0.086 in. w.g. per 100 ft, which is fine for a supply run. A return carrying 400 CFM needs a 12 in duct (509 fpm, 0.036 in. w.g. per 100 ft) to stay under the 700 fpm return limit.<\/p>\n\n<h3>Worked example: 1,000 m\u00b3\/h<\/h3>\n<p>At 0.8 Pa\/m in galvanized steel, 1,000 m\u00b3\/h needs 286 mm. The next common size is 315 mm: 3.56 m\/s and 0.50 Pa\/m. A 400 \u00d7 200 mm rectangle has the same friction as a 305 mm round duct.<\/p>\n\n<h2>Which friction rate to use<\/h2>\n<p>The friction rate is not a constant you pick from a chart. ACCA&#8217;s Manual D calculates it from two numbers: the available static pressure (ASP) and the total effective length (TEL) of the longest run.<\/p>\n<blockquote>&#8220;The available static pressure (ASP) is what\u2019s left when you take the total external static pressure and subtract the pressure drops for all the things that aren\u2019t ducts and fittings.&#8221; <cite>\u2013 <a href=\"https:\/\/hvac-blog.acca.org\/?p=17717\" rel=\"noopener\" target=\"_blank\">ACCA, Calculating Friction Rate \u2013 It\u2019s Not a Constant (2017)<\/a><\/cite><\/blockquote>\n<blockquote>&#8220;The total effective length (TEL) is the sum of the duct lengths and the fitting equivalent lengths.&#8221; <cite>\u2013 <a href=\"https:\/\/hvac-blog.acca.org\/?p=17717\" rel=\"noopener\" target=\"_blank\">ACCA (2017)<\/a><\/cite><\/blockquote>\n<p class=\"formula\">Friction rate (in. w.g. per 100 ft) = ASP \u00d7 100 \u00f7 TEL<\/p>\n<p>Many installers skip the calculation and use 0.1 in. w.g. per 100 ft. ACCA explains that 0.1 sits in the middle of the Manual D chart, which is why it became a habit, and that in one worked design &#8220;if you use 0.1 instead of 0.073, your ducts will be undersized.&#8221; Use the calculated value when you have it, and 0.1 only for a first estimate.<\/p>\n<div class=\"tw\"><table><thead><tr><th>in. w.g. per 100 ft<\/th><th>Pa per metre<\/th><\/tr><\/thead><tbody>\n<tr><td>0.05<\/td><td>0.41<\/td><\/tr><tr><td>0.08<\/td><td>0.65<\/td><\/tr><tr><td>0.10<\/td><td>0.82<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<h2>Velocity limits<\/h2>\n<p>Sizing by friction alone can leave air moving too fast. Energy Vanguard summarises the residential limits in ACCA Manual D: &#8220;In Manual D, Table N3-1 specifies the maximum velocities for supply and return trunks and branches. For supplies, it\u2019s 900 fpm. For returns, it\u2019s 700 fpm.&#8221; That is 4.6 m\/s and 3.6 m\/s. The calculator warns you when the size you picked is above either limit. Commercial and industrial ducts are often designed faster, so use the limit your project specifies.<\/p>\n\n<h2>Quick reference: duct size by airflow<\/h2>\n<p>Galvanized round duct, sized at 0.1 in. w.g. per 100 ft and rounded up to the next common size (1 in steps up to 10 in, then 2 in steps).<\/p>\n<div class=\"tw\"><table><thead><tr><th>Airflow<\/th><th>Exact diameter<\/th><th>Duct size<\/th><th>Velocity at that size<\/th><\/tr><\/thead><tbody>\n<tr><td>100 CFM<\/td><td>5.8 in<\/td><td>6 in<\/td><td>509 fpm<\/td><\/tr>\n<tr><td>200 CFM<\/td><td>7.5 in<\/td><td>8 in<\/td><td>573 fpm<\/td><\/tr>\n<tr><td>400 CFM<\/td><td>9.7 in<\/td><td>10 in<\/td><td>733 fpm<\/td><\/tr>\n<tr><td>600 CFM<\/td><td>11.3 in<\/td><td>12 in<\/td><td>764 fpm<\/td><\/tr>\n<tr><td>800 CFM<\/td><td>12.6 in<\/td><td>14 in<\/td><td>748 fpm<\/td><\/tr>\n<tr><td>1,000 CFM<\/td><td>13.6 in<\/td><td>14 in<\/td><td>935 fpm<\/td><\/tr>\n<tr><td>1,500 CFM<\/td><td>15.9 in<\/td><td>16 in<\/td><td>1,074 fpm<\/td><\/tr>\n<tr><td>2,000 CFM<\/td><td>17.7 in<\/td><td>18 in<\/td><td>1,132 fpm<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>The same in metric, sized at 0.8 Pa\/m:<\/p>\n<div class=\"tw\"><table><thead><tr><th>Airflow<\/th><th>Exact diameter<\/th><th>Duct size<\/th><th>Velocity<\/th><th>Friction at that size<\/th><\/tr><\/thead><tbody>\n<tr><td>100 m\u00b3\/h<\/td><td>122 mm<\/td><td>125 mm<\/td><td>2.26 m\/s<\/td><td>0.70 Pa\/m<\/td><\/tr>\n<tr><td>200 m\u00b3\/h<\/td><td>157 mm<\/td><td>160 mm<\/td><td>2.76 m\/s<\/td><td>0.73 Pa\/m<\/td><\/tr>\n<tr><td>300 m\u00b3\/h<\/td><td>183 mm<\/td><td>200 mm<\/td><td>2.65 m\/s<\/td><td>0.52 Pa\/m<\/td><\/tr>\n<tr><td>500 m\u00b3\/h<\/td><td>221 mm<\/td><td>250 mm<\/td><td>2.83 m\/s<\/td><td>0.44 Pa\/m<\/td><\/tr>\n<tr><td>1,000 m\u00b3\/h<\/td><td>286 mm<\/td><td>315 mm<\/td><td>3.56 m\/s<\/td><td>0.50 Pa\/m<\/td><\/tr>\n<tr><td>1,500 m\u00b3\/h<\/td><td>332 mm<\/td><td>355 mm<\/td><td>4.21 m\/s<\/td><td>0.58 Pa\/m<\/td><\/tr>\n<tr><td>2,000 m\u00b3\/h<\/td><td>370 mm<\/td><td>400 mm<\/td><td>4.42 m\/s<\/td><td>0.55 Pa\/m<\/td><\/tr>\n<tr><td>3,000 m\u00b3\/h<\/td><td>431 mm<\/td><td>450 mm<\/td><td>5.24 m\/s<\/td><td>0.65 Pa\/m<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<h2>Round or rectangular duct<\/h2>\n<p>A rectangular duct carrying the same airflow with the same friction is not the one with the same area. Huebscher&#8217;s equation gives the round diameter with equal friction:<\/p>\n<p class=\"formula\">De = 1.30 \u00d7 (a \u00d7 b)^0.625 \u00f7 (a + b)^0.25<\/p>\n<p>A 10 \u00d7 16 in duct, for example, behaves like a 13.7 in round duct. For a 300 mm round duct (0.071 m\u00b2 of area, 0.94 m of perimeter), the equal-friction rectangles in 50 mm steps are 400 \u00d7 200 mm (0.080 m\u00b2, 1.20 m) and 300 \u00d7 300 mm (0.090 m\u00b2, 1.20 m). The rectangle always needs more sheet metal per metre. The flatter it gets, the more it needs, so keep the aspect ratio low when the ceiling allows.<\/p>\n\n<h2>Duct material and flexible duct<\/h2>\n<p>Rougher walls need bigger ducts. The calculator uses the roughness classes from Caleffi&#8217;s duct pressure loss handbook: 0.03 mm for PVC and aluminium, 0.09 mm for galvanized and stainless steel, 0.9 mm for lined ducts and 3.0 mm for flexible ducts. For 720 m\u00b3\/h at 0.8 Pa\/m, that means 250 mm in PVC, 253 mm in galvanized steel, 268 mm in lined duct and 282 mm in flexible duct.<\/p>\n<p>Flexible duct is only as good as its installation. HPAC, reporting on the ASHRAE research behind the ASHRAE\/ADI duct calculator, notes that compression &#8220;increases the roughness and, therefore, the friction loss inside a flexible duct.&#8221; In Energy Vanguard&#8217;s example, 400 CFM that fits a 10 in flex duct pulled tight needs a 12 in duct if the liner is left with 4% compression.<\/p>\n\n<h2>From duct size to fan<\/h2>\n<p>The duct size alone does not choose the fan. Add up the pressure loss along the longest run: the straight duct (the Check tab gives friction \u00d7 length), the fittings, grilles, filters and any heat exchanger. Then pick a fan whose curve delivers your airflow at that pressure, not just at free air.<\/p>\n<p>To see where a fan will actually run on its curve in your system, use the <a href=\"\/static-pressure-fan-selection\/\">static pressure guide and operating point calculator<\/a>.<\/p>\n<ul>\n  <li>Round ducts from 100 to 315 mm: the <a href=\"\/products\/kcvents-mixed-flow-inline-fan\/\">mixed flow inline fan<\/a> (KC-100 to KC-315) and the <a href=\"\/products\/mixed-flow-inline-fan-kcp-series\/\">KCP mixed flow fan<\/a> (KC-100P to KC-315P).<\/li>\n  <li>100 to 250 mm with low noise: the <a href=\"\/products\/silent-in-line-series\/\">silent galvanized inline duct fan<\/a> (DPT10 to DPT25).<\/li>\n  <li>100 to 150 mm, small rooms: the <a href=\"\/products\/apj-inline-series\/\">APJ small inline fan<\/a>.<\/li>\n  <li>Larger ducts and higher pressure: <a href=\"\/product-category\/ktj-cabinet-fan\/\">cabinet fans<\/a>. If you are choosing between fan types, see <a href=\"\/axial-vs-centrifugal-fan\/\">axial vs centrifugal fans<\/a>.<\/li>\n<\/ul>\n\n<h2>Assumptions and limits<\/h2>\n<ul>\n  <li>Air at 20 \u00b0C and sea level (density 1.204 kg\/m\u00b3). Hot air, cold air and high altitude change the result.<\/li>\n  <li>Straight duct only. Elbows, tees, dampers and grilles add losses that a full design (ACCA Manual D, ASHRAE duct design) accounts for.<\/li>\n  <li>Friction from the Darcy equation with the Altshul\u2013Tsal friction factor; rectangular equivalents from Huebscher. Both formulas are given in the Caleffi handbook listed below.<\/li>\n  <li>&#8220;Common sizes&#8221; are 80\u20131,250 mm in metric and 3\u201348 in in imperial (1 in steps to 10 in, then 2 in). Check what your supplier stocks.<\/li>\n<\/ul>\n\n<h2>Frequently asked questions<\/h2>\n<details><summary>What is a ductulator?<\/summary><p>A ductulator is a duct sizing calculator. It started as a cardboard wheel or slide rule: you line up the airflow with the friction rate and read the duct size and velocity. HPAC described the ASHRAE\/ADI duct calculator as one that &#8220;resembles a wheel-type ductulator similar to those used during the days of slide rules&#8221;. This page does the same calculation on screen, in imperial or metric units.<\/p><\/details>\n<details><summary>What size duct do I need for 400 CFM?<\/summary><p>About 10 in round at 0.1 in. w.g. per 100 ft (exact 9.7 in, 733 fpm in a 10 in duct). For a return run, use 12 in to stay under 700 fpm.<\/p><\/details>\n<details><summary>What size duct do I need for 1,000 CFM?<\/summary><p>About 14 in round at 0.1 in. w.g. per 100 ft (exact 13.6 in). The air then moves at 935 fpm, which is above the 900 fpm residential supply limit, so a home supply trunk would go to 16 in.<\/p><\/details>\n<details><summary>What duct size for 1,000 m\u00b3\/h?<\/summary><p>286 mm exact at 0.8 Pa\/m in galvanized steel, so 315 mm in practice (3.56 m\/s). A 400 \u00d7 200 mm rectangular duct has about the same friction.<\/p><\/details>\n<details><summary>What friction rate should I use?<\/summary><p>Calculate it: available static pressure \u00d7 100 \u00f7 total effective length of the longest run. 0.1 in. w.g. per 100 ft (about 0.8 Pa\/m) is a common starting guess, and ACCA warns it can undersize the ducts when the real value is lower.<\/p><\/details>\n<details><summary>Does the calculator include elbows and fittings?<\/summary><p>No. It sizes straight duct. Add the equivalent length of fittings to the run, or add their pressure losses separately when you total the system pressure for the fan.<\/p><\/details>\n<details><summary>Can I use it for flexible duct?<\/summary><p>Yes, choose &#8220;Flexible duct, pulled tight&#8221;. The result assumes the liner is fully stretched; compressed or sagging flex has a higher friction loss.<\/p><\/details>\n\n<div class=\"cta\">\n  <p><strong>Need a fan for this duct?<\/strong> Send us the airflow, the duct size and the total pressure of your longest run, and we will match a KCVENTS inline, mixed flow or cabinet fan to it on the fan curve.<\/p>\n  <a class=\"btn\" href=\"\/contact\/\">Ask for a fan selection<\/a>\n<\/div>\n\n<h2>Sources<\/h2>\n<ul class=\"src\">\n  <li>Caleffi, <a href=\"https:\/\/www.caleffi.com\/sites\/default\/files\/media\/external-file\/Tables%20et%20diagrammes%20pertes%20de%20charge%20a%C3%A9rauliques_FR.pdf\" rel=\"noopener\" target=\"_blank\">Les pertes de charge dans les conduites a\u00e9rauliques<\/a> (2006): Darcy and Altshul\u2013Tsal equations, Huebscher equivalent diameter, duct roughness classes.<\/li>\n  <li>ACCA, <a href=\"https:\/\/hvac-blog.acca.org\/?p=17717\" rel=\"noopener\" target=\"_blank\">Calculating Friction Rate \u2013 It\u2019s Not a Constant<\/a> (2017).<\/li>\n  <li>ACCA HVAC Skill Builder, <a href=\"https:\/\/hvac-blog.acca.org\/matt-where-does-the-1-friction-rate-commonly-used-to-size-ducts-come-from\/\" rel=\"noopener\" target=\"_blank\">Where Does the .1 Friction Rate Commonly Used to Size Ducts Come From?<\/a><\/li>\n  <li>Energy Vanguard, <a href=\"https:\/\/energyvanguard.com\/blog\/duct-design-5-sizing-ducts\" rel=\"noopener\" target=\"_blank\">Duct Design 5 \u2014 Sizing the Ducts<\/a> (2017): Manual D velocity limits, flexible duct compression example.<\/li>\n  <li>HPAC Engineering, <a href=\"https:\/\/www.hpac.com\/iaq-ventilation\/new-duct-sizing-calculator-available-ashrae-and-adi\" rel=\"noopener\" target=\"_blank\">New Duct-Sizing Calculator Available From ASHRAE and ADI<\/a> (2016).<\/li>\n<\/ul>\n<\/div>\n\n<script>\n(function () {\n\/\/ Duct sizing engine for the \/duct-size-calculator\/ page. Plain functions, SI units inside (m, m3\/s, Pa\/m, m\/s).\n\/\/ build-page.mjs inlines this file into the page (it strips the `export` keywords), so keep it dependency-free.\n\/\/\n\/\/ Sources (Caleffi, \"Les pertes de charge dans les conduites a\u00e9rauliques\", 2006):\n\/\/   Darcy:            dp\/L = f \/ D * rho V^2 \/ 2\n\/\/   Altshul-Tsal:     f' = 0.11 (eps\/D + 68\/Re)^0.25 ; f = f' if f' >= 0.018, else 0.85 f' + 0.0028 ; laminar f = 64\/Re\n\/\/   Huebscher:        De = 1.30 (a b)^0.625 \/ (a + b)^0.25\n\/\/   Roughness classes: very smooth 0.03 mm (PVC, aluminium), smooth 0.09 mm (galvanized, stainless steel),\n\/\/                      rough 0.90 mm (PE \/ glass-fibre lined), very rough 3.00 mm (flexible ducts)\n\nconst STD_AIR = { rho: 1.204, nu: 1.516e-5 }; \/\/ air at 20 \u00b0C, 101.325 kPa\n\nconst MATERIALS = {\n  pvc: { eps: 0.03e-3, label: 'PVC \/ aluminium (very smooth, \u03b5 0.03 mm)' },\n  galvanized: { eps: 0.09e-3, label: 'Galvanized or stainless steel (\u03b5 0.09 mm)' },\n  lined: { eps: 0.9e-3, label: 'Lined duct, PE or glass fibre (\u03b5 0.9 mm)' },\n  flexible: { eps: 3.0e-3, label: 'Flexible duct, pulled tight (\u03b5 3.0 mm)' },\n};\n\nconst IN = 0.0254;\nconst SERIES = {\n  metric: [0.08, 0.1, 0.125, 0.15, 0.16, 0.2, 0.25, 0.315, 0.355, 0.4, 0.45, 0.5, 0.56, 0.63, 0.71, 0.8, 0.9, 1.0, 1.12, 1.25],\n  inch: [3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 40, 44, 48].map((x) => x * IN),\n};\n\nconst toSI = {\n  flow: (v, u) => v * { m3h: 1 \/ 3600, cfm: 0.00047194745, ls: 0.001, m3s: 1 }[u],\n  friction: (v, u) => v * { pam: 1, iwg100ft: 249.0889 \/ 30.48 }[u],\n  velocity: (v, u) => v * { ms: 1, fpm: 0.00508 }[u],\n  length: (v, u) => v * { mm: 0.001, in: IN, m: 1 }[u],\n};\nconst fromSI = {\n  flow: (v, u) => v \/ toSI.flow(1, u),\n  friction: (v, u) => v \/ toSI.friction(1, u),\n  velocity: (v, u) => v \/ toSI.velocity(1, u),\n  length: (v, u) => v \/ toSI.length(1, u),\n  pressure: (v, u) => v * { pa: 1, iwg: 1 \/ 249.0889 }[u],\n};\n\nfunction frictionFactor(d, eps, re) {\n  if (re < 2000) return 64 \/ re;\n  const f = 0.11 * (eps \/ d + 68 \/ re) ** 0.25;\n  return f >= 0.018 ? f : 0.85 * f + 0.0028;\n}\n\nconst area = (d) => (Math.PI * d * d) \/ 4;\n\nfunction frictionRate(q, d, eps, air = STD_AIR) {\n  const v = q \/ area(d);\n  const re = (v * d) \/ air.nu;\n  return (frictionFactor(d, eps, re) \/ d) * ((air.rho * v * v) \/ 2);\n}\n\nfunction diameterForFriction(q, target, eps, air = STD_AIR) {\n  let lo = Math.log(0.005), hi = Math.log(10);\n  for (let i = 0; i < 200; i++) {\n    const mid = (lo + hi) \/ 2;\n    if (frictionRate(q, Math.exp(mid), eps, air) > target) lo = mid; else hi = mid;\n  }\n  return Math.exp((lo + hi) \/ 2);\n}\n\nconst diameterForVelocity = (q, v) => Math.sqrt((4 * q) \/ (Math.PI * v));\n\nconst equivalentDiameter = (a, b) => (1.3 * (a * b) ** 0.625) \/ (a + b) ** 0.25;\n\nfunction nextSize(d, series) {\n  for (const s of series) if (d <= s * (1 + 1e-9)) return s;\n  return null;\n}\n\n\/\/ Rectangles with the same friction as a round duct of diameter `de`: for each common height, the narrowest width\n\/\/ (rounded up to 50 mm or 2 in) whose Huebscher equivalent diameter is at least `de`. Aspect ratio up to 4:1.\nfunction rectangles(de, system) {\n  const step = system === 'inch' ? 2 * IN : 0.05;\n  const heights = system === 'inch'\n    ? [4, 6, 8, 10, 12, 14, 16, 18, 20, 24, 30, 36, 42, 48].map((x) => x * IN)\n    : [0.1, 0.15, 0.2, 0.25, 0.3, 0.35, 0.4, 0.5, 0.6, 0.8, 1.0, 1.2];\n  const rows = [];\n  for (const h of heights) {\n    let w = Math.max(h, Math.ceil(h \/ step - 1e-9) * step);\n    while (equivalentDiameter(w, h) < de - 1e-12) w += step;\n    w = Math.round(w \/ step) * step;\n    if (w \/ h > 4 + 1e-9) continue;\n    rows.push({ w, h, ratio: w \/ h, de: equivalentDiameter(w, h), area: w * h, perimeter: 2 * (w + h) });\n    if (Math.abs(w - h) < 1e-9) break; \/\/ square reached: taller would only waste height\n  }\n  return rows;\n}\n\nfunction checkDuct(q, shape, eps, air = STD_AIR) {\n  const isRound = shape.d != null;\n  const de = isRound ? shape.d : equivalentDiameter(shape.w, shape.h);\n  const a = isRound ? area(shape.d) : shape.w * shape.h;\n  const velocity = q \/ a;\n  return {\n    de, area: a, velocity,\n    friction: frictionRate(q, de, eps, air),\n    vp: (air.rho * velocity * velocity) \/ 2,\n  };\n}\n\n\/\/ Size a duct: method 'friction' (target Pa\/m) or 'velocity' (max m\/s). Returns the exact diameter, the next common\n\/\/ size with the friction and velocity you will actually get there, and rectangular options.\nfunction size({ q, method, target, eps, system }) {\n  const exact = method === 'velocity' ? diameterForVelocity(q, target) : diameterForFriction(q, target, eps);\n  const series = SERIES[system === 'inch' ? 'inch' : 'metric'];\n  const pick = nextSize(exact, series);\n  const at = (d) => ({ d, ...checkDuct(q, { d }, eps) });\n  return {\n    exact: at(exact),\n    next: pick ? at(pick) : null,\n    rect: rectangles(exact, system).map((r) => ({ ...r, ...checkDuct(q, { w: r.w, h: r.h }, eps) })),\n  };\n}\n\n  var $ = function (id) { return document.getElementById(id); };\n  var app = $('kcd-app'); if (!app) return;\n  var root = app.parentNode;\n  var st = { sys: 'inch', mode: 'size' }; \/\/ IN (0.0254 m) comes from the inlined engine\n  var fanSizes = [\n    { name: 'Mixed flow inline fan KC', url: '\/products\/kcvents-mixed-flow-inline-fan\/', mm: [100, 125, 150, 200, 250, 315] },\n    { name: 'KCP mixed flow fan', url: '\/products\/mixed-flow-inline-fan-kcp-series\/', mm: [100, 125, 150, 200, 250, 315] },\n    { name: 'Silent galvanized inline duct fan DPT', url: '\/products\/silent-in-line-series\/', mm: [100, 150, 200, 250] },\n    { name: 'APJ small inline fan', url: '\/products\/apj-inline-series\/', mm: [100, 125, 150] }\n  ];\n  function num(id) { var v = parseFloat($(id).value); return isFinite(v) ? (v > 0 ? v : null) : null; }\n  function fmt(x, d) { return x.toLocaleString('en-US', { minimumFractionDigits: d, maximumFractionDigits: d }); }\n  var imp = function () { return st.sys === 'inch'; };\n  function inch(m) { var x = m \/ IN; return fmt(x, Math.abs(x - Math.round(x)) < 0.005 ? 0 : 1) + ' in'; }\n  function len(m) { return imp() ? inch(m) : fmt(m * 1000, 0) + ' mm'; }\n  function lenAlt(m) { return imp() ? fmt(m * 1000, 0) + ' mm' : fmt(m \/ IN, 1) + ' in'; }\n  function vel(v) { return imp() ? fmt(v \/ 0.00508, 0) + ' fpm' : fmt(v, 2) + ' m\/s'; }\n  function velAlt(v) { return imp() ? fmt(v, 2) + ' m\/s' : fmt(v \/ 0.00508, 0) + ' fpm'; }\n  function fr(r) { return imp() ? fmt(fromSI.friction(r, 'iwg100ft'), 3) + ' in. w.g.\/100 ft' : fmt(r, 2) + ' Pa\/m'; }\n  function frAlt(r) { return imp() ? fmt(r, 2) + ' Pa\/m' : fmt(fromSI.friction(r, 'iwg100ft'), 3) + ' in. w.g.\/100 ft'; }\n  function pr(p) { return imp() ? fmt(p \/ 249.0889, 3) + ' in. w.g.' : fmt(p, 1) + ' Pa'; }\n  function show(el, on) { el.classList.toggle('hide', !on); }\n  function flowSI(v) { return imp() ? toSI.flow(v, 'cfm') : toSI.flow(v, $('kcd-qu').value); }\n  function lenIn(v) { return imp() ? v * IN : v \/ 1000; }\n  function warn(prefix, v) {\n    show($(prefix + 'sup'), v > 4.572 + 1e-9);\n    show($(prefix + 'ret'), v > 3.556 + 1e-9 ? v <= 4.572 + 1e-9 : false);\n  }\n  function run() {\n    var q = num('kcd-q'); var eps = MATERIALS[$('kcd-mat').value].eps;\n    if (!q) return;\n    var Q = flowSI(q);\n    if (st.mode === 'size') {\n      var method = root.querySelector('input[name=\"kcd-m\"]:checked').value;\n      var t = method === 'velocity' ? num('kcd-v') : num('kcd-fr');\n      if (!t) return;\n      var target = method === 'velocity' ? toSI.velocity(t, imp() ? 'fpm' : 'ms') : toSI.friction(t, imp() ? 'iwg100ft' : 'pam');\n      var r = size({ q: Q, method: method, target: target, eps: eps, system: st.sys });\n      $('kcd-exact').textContent = len(r.exact.d); $('kcd-exact2').textContent = lenAlt(r.exact.d);\n      show($('kcd-warn-big'), !r.next);\n      var n = r.next || r.exact;\n      $('kcd-next').textContent = r.next ? len(r.next.d) : '\u2013'; $('kcd-next2').textContent = r.next ? lenAlt(r.next.d) : '';\n      $('kcd-nv').textContent = vel(n.velocity); $('kcd-nf').textContent = fr(n.friction); $('kcd-np').textContent = pr(n.vp);\n      warn('kcd-warn-', n.velocity);\n      var rows = r.rect.map(function (x) {\n        return '<tr><td>' + (imp() ? fmt(x.w \/ IN, 0) + ' \u00d7 ' + fmt(x.h \/ IN, 0) + ' in' : fmt(x.w * 1000, 0) + ' \u00d7 ' + fmt(x.h * 1000, 0) + ' mm') + '<\/td><td>' + fmt(x.ratio, 1) + ' : 1<\/td><td>' + len(x.de) + '<\/td><td>' + vel(x.velocity) + '<\/td><td>' + fr(x.friction) + '<\/td><\/tr>';\n      });\n      $('kcd-rect').innerHTML = rows.join('');\n      var mm = nextSize(r.exact.d, SERIES.metric);\n      var list = mm ? fanSizes.filter(function (f) { return f.mm.indexOf(Math.round(mm * 1000)) >= 0; }) : [];\n      $('kcd-fanlist').innerHTML = list.map(function (f) { return '<li><a href=\"' + f.url + '\">' + f.name + '<\/a> \u2013 ' + Math.round(mm * 1000) + ' mm<\/li>'; }).join('');\n      show($('kcd-fanlist'), list.length > 0);\n      show($('kcd-fanbig'), !mm || mm > 0.3151);\n      show($('kcd-fans'), list.length > 0 || !mm || mm > 0.3151);\n    } else {\n      var shape = root.querySelector('input[name=\"kcd-shape\"]:checked').value;\n      var c;\n      if (shape === 'round') { var d = num('kcd-d'); if (!d) return; c = checkDuct(Q, { d: lenIn(d) }, eps); }\n      else { var w = num('kcd-w'), h = num('kcd-h'); if (!w || !h) return; c = checkDuct(Q, { w: lenIn(w), h: lenIn(h) }, eps); }\n      var L = parseFloat($('kcd-len').value); L = (isFinite(L) ? L > 0 : false) ? (imp() ? L * 0.3048 : L) : 0;\n      $('kcd-cv').textContent = vel(c.velocity); $('kcd-cv2').textContent = velAlt(c.velocity);\n      $('kcd-cf').textContent = fr(c.friction); $('kcd-cf2').textContent = frAlt(c.friction);\n      $('kcd-cl').textContent = L ? pr(c.friction * L) : '\u2013';\n      $('kcd-ce').textContent = len(c.de); $('kcd-cp').textContent = pr(c.vp);\n      warn('kcd-cwarn-', c.velocity);\n    }\n  }\n  function setSys(sys) {\n    if (sys === st.sys) return;\n    var toMet = sys === 'metric';\n    var qv = num('kcd-q'), fv = num('kcd-fr'), vv = num('kcd-v'), dv = num('kcd-d'), wv = num('kcd-w'), hv = num('kcd-h'), lv = parseFloat($('kcd-len').value);\n    if (qv) $('kcd-q').value = toMet ? Math.round(fromSI.flow(toSI.flow(qv, 'cfm'), $('kcd-qu').value)) : Math.round(fromSI.flow(toSI.flow(qv, $('kcd-qu').value), 'cfm'));\n    if (fv) $('kcd-fr').value = toMet ? +fmt(toSI.friction(fv, 'iwg100ft'), 2) : +fmt(fromSI.friction(fv, 'iwg100ft'), 3);\n    if (vv) $('kcd-v').value = toMet ? +fmt(vv * 0.00508, 1) : Math.round(vv \/ 0.00508);\n    if (dv) $('kcd-d').value = toMet ? Math.round(dv * 25.4) : +fmt(dv \/ 25.4, 1);\n    if (wv) $('kcd-w').value = toMet ? Math.round(wv * 25.4) : +fmt(wv \/ 25.4, 1);\n    if (hv) $('kcd-h').value = toMet ? Math.round(hv * 25.4) : +fmt(hv \/ 25.4, 1);\n    if (isFinite(lv)) $('kcd-len').value = toMet ? +fmt(lv * 0.3048, 1) : Math.round(lv \/ 0.3048);\n    st.sys = sys;\n    root.querySelectorAll('[data-imp]').forEach(function (e) { show(e, !toMet); });\n    root.querySelectorAll('[data-met]').forEach(function (e) { show(e, toMet); });\n    app.querySelectorAll('[data-sys]').forEach(function (b) { b.setAttribute('aria-pressed', b.getAttribute('data-sys') === sys); });\n    run();\n  }\n  function setMode(mode) {\n    st.mode = mode;\n    root.querySelectorAll('[data-for]').forEach(function (e) { show(e, e.getAttribute('data-for') === mode); });\n    app.querySelectorAll('[data-mode]').forEach(function (b) { b.setAttribute('aria-pressed', b.getAttribute('data-mode') === mode); });\n    run();\n  }\n  app.querySelectorAll('[data-sys]').forEach(function (b) { b.addEventListener('click', function () { setSys(b.getAttribute('data-sys')); }); });\n  app.querySelectorAll('[data-mode]').forEach(function (b) { b.addEventListener('click', function () { setMode(b.getAttribute('data-mode')); }); });\n  root.querySelectorAll('input[name=\"kcd-m\"]').forEach(function (r) { r.addEventListener('change', function () { var v = r.checked ? r.value === 'velocity' : false; show($('kcd-vbox'), v); show($('kcd-fbox'), !v); run(); }); });\n  root.querySelectorAll('input[name=\"kcd-shape\"]').forEach(function (r) { r.addEventListener('change', function () { var rr = r.checked ? r.value === 'rect' : false; show($('kcd-rbox'), rr); show($('kcd-dbox'), !rr); run(); }); });\n  var qu = $('kcd-qu'); var lastQu = qu.value;\n  qu.addEventListener('change', function () { var v = num('kcd-q'); if (v) $('kcd-q').value = Math.round(fromSI.flow(toSI.flow(v, lastQu), qu.value)); lastQu = qu.value; run(); });\n  app.addEventListener('input', run);\n  app.addEventListener('change', run);\n  run();\n})();\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>Ductulator: Duct Size Calculator for Round and Rectangular Ducts Enter the airflow and either a design friction rate or a maximum air velocity. This ductulator returns the round duct diameter, the next common size, rectangular ducts with the same pressure loss, and the velocity and friction you will actually get at each size. It works [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","iawp_total_views":2,"footnotes":""},"class_list":["post-4718","page","type-page","status-publish","hentry"],"blocksy_meta":{"has_hero_section":"disabled"},"_links":{"self":[{"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/pages\/4718","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/comments?post=4718"}],"version-history":[{"count":2,"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/pages\/4718\/revisions"}],"predecessor-version":[{"id":4725,"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/pages\/4718\/revisions\/4725"}],"wp:attachment":[{"href":"https:\/\/www.kcvents.com\/de\/wp-json\/wp\/v2\/media?parent=4718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}