{"id":1049,"date":"2026-06-03T20:02:46","date_gmt":"2026-06-03T12:02:46","guid":{"rendered":"https:\/\/www.kcvents.com\/?post_type=product&#038;p=1049"},"modified":"2026-09-07T19:54:03","modified_gmt":"2026-09-07T11:54:03","slug":"ec-energy-recovery-ventilator","status":"publish","type":"product","link":"https:\/\/www.kcvents.com\/fr\/produits\/ec-energy-recovery-ventilator\/","title":{"rendered":"Ventilateur r\u00e9cup\u00e9rateur d'\u00e9nergie EC"},"content":{"rendered":"<div class=\"kc-ptc-wrap\">\n<section id=\"overview\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">System Overview<\/span><\/h2>\n<div>\n<p>EC Energy Recovery Ventilator delivers balanced whole-house ventilation for residential and light commercial projects: it supplies fresh outdoor air while exhausting stale indoor air, and the heat recovery core transfers energy between the two streams to reduce heating and cooling loss.<\/p>\n<p>The EC motor provides variable-speed control, which keeps operation efficient and quieter across partial-load conditions. With models ranging from 90~180 m\u00b3\/h up to 480~800 m\u00b3\/h airflow, the series covers compact homes through larger whole-house and project installations.<\/p>\n<\/div>\n<\/section>\n<section id=\"features-benefits\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Core Engineering Features<\/span><\/h2>\n<p class=\"kc-sec-lead\">Designed for dependable whole-house recovery ventilation with efficient motor control, recoverable thermal energy and simple installation.<\/p>\n<div class=\"kc-grid-3\">\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag blue\">EC MOTOR<\/div>\n<h3 class=\"kc-feature-title\">Variable-speed control<\/h3>\n<p class=\"kc-feature-desc\">EC motor with variable speed adjusts airflow to demand, lowering power use and noise during partial-load operation.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag amber\">HEAT RECOVERY<\/div>\n<h3 class=\"kc-feature-title\">Recovery core<\/h3>\n<p class=\"kc-feature-desc\">Heat exchange rates up to 82% in heating mode help keep indoor comfort stable while reducing energy loss.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag green\">AIR QUALITY<\/div>\n<h3 class=\"kc-feature-title\">Washable filter system<\/h3>\n<p class=\"kc-feature-desc\">Washable or replaceable filters block dust and pollutants while the unit runs continuous fresh-air supply.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag purple\">QUIET RUNNING<\/div>\n<h3 class=\"kc-feature-title\">Low-noise operation<\/h3>\n<p class=\"kc-feature-desc\">31\u201341 dB noise range across the model line supports residential and low-noise project environments.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag teal\">FLEXIBLE MOUNTING<\/div>\n<h3 class=\"kc-feature-title\">Wall or ceiling mount<\/h3>\n<p class=\"kc-feature-desc\">Compact unit size with straightforward installation and wiring for retrofit and new-build projects.<\/p>\n<\/div>\n<div class=\"kc-card\">\n<div class=\"kc-feature-tag gray\">MODEL RANGE<\/div>\n<h3 class=\"kc-feature-title\">90\u2013800 m\u00b3\/h coverage<\/h3>\n<p class=\"kc-feature-desc\">Six models from CHQR-180EC to CHQR-800EC with \u00d8100\u2013\u00d8200 mm duct options for different project layouts.<\/p>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"technical-specifications\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Technical Specifications<\/span><\/h2>\n<div style=\"margin-bottom: 24px\">\n<h3 class=\"kc-spec-heading\"><i class=\"fa-solid fa-sliders\"><\/i> Dimension Table (unit: mm)<\/h3>\n<div class=\"kc-table-wrap\">\n<table class=\"kc-table\">\n<thead>\n<tr>\n<th>Model<\/th>\n<th>A<\/th>\n<th>B<\/th>\n<th>C<\/th>\n<th>D<\/th>\n<th>E<\/th>\n<th>F<\/th>\n<th>G<\/th>\n<th>H<\/th>\n<th>I<\/th>\n<th>J<\/th>\n<th>K<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CHQR &#8211; 180EC<\/td>\n<td>856<\/td>\n<td>750<\/td>\n<td>95<\/td>\n<td>12<\/td>\n<td>305<\/td>\n<td>536<\/td>\n<td>597<\/td>\n<td>186<\/td>\n<td>305<\/td>\n<td>536<\/td>\n<td>582<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 350EC<\/td>\n<td>894<\/td>\n<td>780<\/td>\n<td>145<\/td>\n<td>12<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<td>208<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 450EC<\/td>\n<td>984<\/td>\n<td>780<\/td>\n<td>145<\/td>\n<td>21<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<td>208<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 550EC<\/td>\n<td>894<\/td>\n<td>780<\/td>\n<td>145<\/td>\n<td>12<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<td>208<\/td>\n<td>330<\/td>\n<td>618<\/td>\n<td>665<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 600EC<\/td>\n<td>1096<\/td>\n<td>985<\/td>\n<td>195<\/td>\n<td>12<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<td>272<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 800EC<\/td>\n<td>1096<\/td>\n<td>985<\/td>\n<td>195<\/td>\n<td>12<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<td>272<\/td>\n<td>438<\/td>\n<td>776<\/td>\n<td>822<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<div style=\"margin-bottom: 24px\">\n<h3 class=\"kc-spec-heading\"><i class=\"fa-solid fa-sliders\"><\/i> Parameter Table<\/h3>\n<div class=\"kc-table-wrap\">\n<table class=\"kc-table\">\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Voltage (V\/Hz)<\/th>\n<th>Airflow (m\u00b3\/h)<\/th>\n<th>Static Pressure (Pa)<\/th>\n<th>Power (W)<\/th>\n<th>Heat Exchange Rate (%) [Cooling\/Heating]<\/th>\n<th>Enthalpy Exchange Rate (%) [Cooling\/Heating]<\/th>\n<th>Noise (dB)<\/th>\n<th>Duct Size (mm)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>CHQR &#8211; 180EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>90~180<\/td>\n<td>115<\/td>\n<td>10~46<\/td>\n<td>60 \/ 79<\/td>\n<td>60 \/ 71<\/td>\n<td>31<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 350EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>190~350<\/td>\n<td>122<\/td>\n<td>13~56<\/td>\n<td>61 \/ 79<\/td>\n<td>60 \/ 69<\/td>\n<td>33<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 450EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>220~450<\/td>\n<td>146<\/td>\n<td>15~88<\/td>\n<td>60 \/ 78<\/td>\n<td>60 \/ 70<\/td>\n<td>35<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 550EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>225~550<\/td>\n<td>158<\/td>\n<td>15~110<\/td>\n<td>58 \/ 80<\/td>\n<td>58 \/ 68<\/td>\n<td>38<\/td>\n<td>150<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 600EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>385~650<\/td>\n<td>197<\/td>\n<td>33~190<\/td>\n<td>58 \/ 82<\/td>\n<td>58 \/ 68<\/td>\n<td>40<\/td>\n<td>200<\/td>\n<\/tr>\n<tr>\n<td>CHQR &#8211; 800EC<\/td>\n<td>180V~240\/50\/60<\/td>\n<td>480~800<\/td>\n<td>239<\/td>\n<td>45~260<\/td>\n<td>58 \/ 82<\/td>\n<td>58 \/ 67<\/td>\n<td>41<\/td>\n<td>200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"performance-curves\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Performance Curves<\/span><\/h2>\n<div class=\"kc-panel\">\n<p class=\"kc-sec-lead\">EC series airflow and static-pressure performance can be reviewed visually before model selection.<\/p>\n<div style=\"text-align: center\">\n<img decoding=\"async\" style=\"max-width: 100%;height: auto;border-radius: 6px\" src=\"\/wp-content\/uploads\/2026\/08\/kcqr-ec-xiao.webp\" alt=\"EC Energy Recovery Ventilator performance curves\" \/>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"applications\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Target Applications<\/span><\/h2>\n<p class=\"kc-sec-lead\">Whole-house recovery ventilation for spaces that need continuous fresh air without wasting thermal energy.<\/p>\n<div class=\"kc-apps-wrap\">\n<div class=\"kc-grid-3\">\n<div class=\"kc-app-card app-residential\">\n<div class=\"kc-app-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"52\" height=\"52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M3 11l9-8 9 8\"><\/path><path d=\"M5 10v11h14V10\"><\/path><path d=\"M9 21v-6h6v6\"><\/path><path d=\"M9 11h1\"><\/path><path d=\"M14 11h1\"><\/path><\/svg><\/div>\n<h3 class=\"kc-app-title\">Homes &amp; Apartments<\/h3>\n<p class=\"kc-app-desc\">Balanced fresh-air delivery for houses and apartments that want stable indoor comfort with less energy loss.<\/p>\n<\/div>\n<div class=\"kc-app-card app-commercial\">\n<div class=\"kc-app-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"52\" height=\"52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M4 10h16\"><\/path><path d=\"M5 10l1-5h12l1 5\"><\/path><path d=\"M6 10v9h12v-9\"><\/path><path d=\"M9 19v-5h6v5\"><\/path><path d=\"M6 10c0 1.1.9 2 2 2s2-.9 2-2\"><\/path><path d=\"M10 10c0 1.1.9 2 2 2s2-.9 2-2\"><\/path><path d=\"M14 10c0 1.1.9 2 2 2s2-.9 2-2\"><\/path><\/svg><\/div>\n<h3 class=\"kc-app-title\">Light Commercial<\/h3>\n<p class=\"kc-app-desc\">Offices, clinics, classrooms and project spaces that need dependable recovery ventilation without a large ducted system.<\/p>\n<\/div>\n<div class=\"kc-app-card app-industrial\">\n<div class=\"kc-app-icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"52\" height=\"52\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.6\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M3 21h18\"><\/path><path d=\"M5 21V9l5 3V9l5 3V5h4v16\"><\/path><path d=\"M9 21v-4h2v4\"><\/path><path d=\"M15 21v-4h2v4\"><\/path><path d=\"M7 14h1\"><\/path><path d=\"M12 14h1\"><\/path><path d=\"M17 14h1\"><\/path><\/svg><\/div>\n<h3 class=\"kc-app-title\">Retrofit &amp; Projects<\/h3>\n<p class=\"kc-app-desc\">Wall- or ceiling-mount units suit renovation projects and repeat B2B supply programs with configurable model selection.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"quality-assurance\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Quality Assurance<\/span><\/h2>\n<p class=\"kc-sec-lead\">Project supply is checked against structure, airflow and noise targets before release.<\/p>\n<div class=\"kc-panel\">\n<div class=\"kc-grid-2\">\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">Heat-Exchanger Sealing<\/h3>\n<p class=\"kc-feature-desc\">Core sealing and airflow path consistency checked against published project specifications.<\/p>\n<\/div>\n<\/div>\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">EC Motor Performance<\/h3>\n<p class=\"kc-feature-desc\">Motor load and efficiency reviewed for stable long-hour operation.<\/p>\n<\/div>\n<\/div>\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">Airflow Balance<\/h3>\n<p class=\"kc-feature-desc\">Supply and exhaust airflow balance verified for whole-house deployment.<\/p>\n<\/div>\n<\/div>\n<div class=\"kc-feature-item\">\n<div class=\"kc-feature-content\">\n<h3 class=\"kc-feature-title\">Noise Verification<\/h3>\n<p class=\"kc-feature-desc\">Published dB targets checked against factory data before release.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<section id=\"certifications\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">Certifications &amp; Compliance<\/span><\/h2>\n<div class=\"kc-panel\">\n<div class=\"kcvents-cert-list\" style=\"display:flex;flex-wrap:wrap;gap:10px\"><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">ISO 9001<\/span><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">.WeDrive<\/span><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">ERV IEC TEST REPORT<\/span><span class=\"kcvents-cert\" style=\"padding:8px 14px;border:1px solid #e5e7eb;border-radius:999px;background:#f8fafc;color:#374151;font-size:14px;font-weight:700\">KCQR ERP 150 350 500<\/span><\/div>\n<\/div>\n<\/section>\n<section id=\"oem-odm-warranty\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">OEM\/ODM &amp; Project Support<\/span><\/h2>\n<div class=\"kc-panel\">\n<p>KCVENTS supports OEM\/ODM services, private-label supply, regional plug and voltage options, catalog documentation and warranty support for qualified project and distributor orders.<\/p>\n<p>Warranty and service terms are confirmed according to the final order agreement.<\/p>\n<\/div>\n<\/section>\n<section id=\"faq\" class=\"kc-ptc-section\">\n<h2 class=\"kc-sec-title-left\"><span class=\"kc-title-line\">FAQ<\/span><\/h2>\n<div class=\"kc-panel\">\n<div class=\"kc-faq-item\">\n<details>\n<summary>What models are available in the EC series?<\/summary>\n<p>The series covers CHQR-180EC, CHQR-350EC, CHQR-450EC, CHQR-550EC, CHQR-600EC and CHQR-800EC, with airflow from 90~180 m\u00b3\/h up to 480~800 m\u00b3\/h.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>What is the maximum heat recovery efficiency?<\/summary>\n<p>Heat exchange rate reaches up to 82% in heating mode and 61% in cooling mode across the model range; duct size options are \u00d8100 mm, \u00d8150 mm and \u00d8200 mm.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>What voltage does the unit support?<\/summary>\n<p>All models accept 180V~240V at 50\/60 Hz, which covers most residential and light commercial mains supplies.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>Can the filters be cleaned?<\/summary>\n<p>Yes. The washable or replaceable filter system is designed for routine maintenance without special tools.<\/p>\n<\/details>\n<\/div>\n<div class=\"kc-faq-item\">\n<details>\n<summary>Does KCVENTS support OEM\/ODM orders for this product?<\/summary>\n<p>Yes. OEM branding, control options, documentation and regional voltage configurations can be reviewed for qualified project and distributor orders.<\/p>\n<\/details>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Ce ventilateur r\u00e9cup\u00e9rateur d'\u00e9nergie (VRE) EC pour l'ensemble de l'habitation fournit un apport d'air neuf \u00e9quilibr\u00e9, r\u00e9duit les d\u00e9perditions thermiques et assure une commande efficace du moteur EC pour les projets r\u00e9sidentiels et de petit tertiaire.<\/p>\n<ul class=\"kcvents-short-points\">\n<li>Moteur EC \u00e0 vitesse variable pour un fonctionnement silencieux et \u00e9conome en \u00e9nergie<\/li>\n<li>\u00c9changeur de r\u00e9cup\u00e9ration de chaleur offrant une efficacit\u00e9 thermique jusqu'\u00e0 82%<\/li>\n<li>Alimentation continue en air neuf avec d\u00e9bit de soufflage et d'extraction \u00e9quilibr\u00e9<\/li>\n<li>Filtres lavables ou rempla\u00e7ables pour bloquer la poussi\u00e8re et les polluants<\/li>\n<li>Conception compacte pour montage mural ou plafonnier facilitant l'installation<\/li>\n<\/ul>","protected":false},"featured_media":2426,"comment_status":"open","ping_status":"closed","template":"","meta":{"_gspb_post_css":"","iawp_total_views":21},"product_brand":[],"product_cat":[23],"product_tag":[],"class_list":["post-1049","product","type-product","status-publish","has-post-thumbnail","product_cat-whole-house-erv-hrv-systems","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/product\/1049","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/comments?post=1049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/media\/2426"}],"wp:attachment":[{"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/media?parent=1049"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1049"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1049"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.kcvents.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1049"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}