The bathroom fan nobody has to think about. It starts when the shower steams up the room, keeps going after you leave and switches off once the air is dry. On the wall it is a pane of white glass with a temperature and humidity readout, not a plastic grille.
Most bathroom mold has a simple cause: the fan is switched off with the light, while the walls, the ceiling and the silicone joints are still wet. The MFE takes that decision away from the user. It starts by itself when shower steam raises the humidity, keeps running after everyone has left, and switches off once the air is dry.
It also does not look like a fan. What you see on the wall is a pane of white tempered glass with a small LED readout of room temperature and humidity. In a tiled, modern bathroom it reads as a design detail, which is exactly why homeowners accept it in a visible spot and why it is easy to sell.
| With a basic switched fan | With the MFE |
|---|---|
| The fan stops when the light goes off. Moisture stays on the walls and mold appears in corners and joints. | The humidity sensor keeps the fan running until the air has dried, then the timer adds another 3 to 15 minutes. |
| Someone has to remember to switch it on, and guests, children and tenants usually do not. | It starts on its own when humidity passes the level you set, anywhere from 40% to 95% RH. |
| The fan is loud, so people turn it off as soon as they can. | A pure copper motor on ball bearings, rated at a maximum of 31 dB (MFE10) and 33 dB (MFE12). Quiet enough to be left to do its job. |
| The motor wears and gets louder, and replacing a fan in a finished, tiled bathroom is a nuisance. | Ball bearings and built-in thermal overload protection, with a theoretical service life of 30,000 hours. |
| A windowless bathroom stays damp between showers. | The 24-hour mode keeps air moving at reduced speed after each cycle. |
| A plastic grille that collects dust in its slats and looks like an afterthought. | A flat glass panel that wipes clean, with the airflow drawn in around its edges. |
Six things that change in daily use once the fan is on the wall.
Step into the shower and the fan starts when the air turns humid. Nobody reaches for a switch with wet hands, and nobody forgets.
The fan keeps extracting for 3 to 15 minutes after switch-off, so the mirror clears and the walls dry while you get on with your day.
Switch on the S1 setting and the fan continues at reduced speed for up to 24 hours after each cycle. Moisture has no chance to build up between showers.
White tempered glass sits flat against the tiles. The LED readout shows temperature and relative humidity at a glance, so you can see the room drying.
A pure copper motor on ball bearings keeps it to 31 to 33 dB at most and 10 to 12 W. Two hours of running a day at 10 W comes to about 7 kWh a year.
The glass front comes off with the key supplied in the box. Panel and impeller can be rinsed under the tap, at up to 60 °C.
Why the MFE is simple to stock, specify and sell.
| Parameter | MFE10 | MFE12 |
|---|---|---|
| Duct diameter | Ø100 mm (spigot Ø96 mm) | Ø120 mm (spigot Ø116 mm) |
| Maximum airflow | 115 m³/h (68 CFM) | 210 m³/h (124 CFM) |
| Power | 10 W | 12 W |
| Maximum noise level | 31 dB | 33 dB |
| Dimensions (W × D × H) | 150 × 133 × 150 mm | 170 × 135 × 170 mm |
| Mounting hole spacing | 110 mm | 135 mm |
| Rated voltage / frequency | 220–240 V~, 50/60 Hz | |
| Ingress protection | IPX4 (splash-proof) | |
| Electric shock protection | Class II, double insulated (no earth connection required) | |
| Humidity sensor range | 40%–95% RH, adjustable | |
| Run-on timer range | 3–15 minutes, adjustable | |
| Continuous mode | Reduced speed, up to 24 hours (S1 switch) | |
| Display | LED, room temperature (°C) and relative humidity (%) | |
| Front panel | White tempered glass | |
| Motor | Pure copper winding, ball bearings, thermal overload protection | |
| Design service life | 30,000 hours (theoretical) | |
| Ambient temperature | −5 °C to 40 °C | |
| Conformity | CE: Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU | |

Toilets, en-suites and small to medium bathrooms with a short duct run through the wall.
Larger bathrooms, shower rooms used several times a day, and installations with a longer duct.
A common rule of thumb for bathrooms is 6 to 8 air changes per hour. A 6 m² bathroom with a 2.5 m ceiling holds 15 m³ of air, so it needs roughly 90 to 120 m³/h. The airflow figures above are maximum values, so allow a margin for the resistance of the duct and any external grille.
The timer and the humidity level are set once at installation, with the adjusting key, on two dials behind the front panel. After that the fan needs no attention.
| Situation | What the fan does |
|---|---|
| Wall switch turned off | Keeps running for the set time (3–15 minutes), then stops |
| Humidity rises above the set level | Runs continuously |
| Humidity falls below the set level | Runs on for the set time, then stops |
| S1 switch set to ON | After the timer period, continues at reduced speed and stops automatically after 24 hours |




Several showers a day and nobody in charge of the fan. The sensor does the remembering.
Rooms that cannot be aired through a window get continuous low-speed ventilation in 24-hour mode.
Landlords and developers get mold protection that does not depend on tenant behavior, in a finish that suits a new bathroom.
MFE10 and MFE12 were tested by Shenzhen Anteng Testing Technology Co., Ltd. in July 2026 and found in conformity with the EU Low Voltage and EMC Directives.
EN IEC 60335-2-80:2024+A11:2024, EN IEC 60335-1:2023+A11:2023, EN 62233:2008. View certificate (PDF)
EN IEC 55014-1:2021, EN IEC 55014-2:2021, EN IEC 61000-3-2:2019+A2:2024, EN 61000-3-3:2013+A2:2021. View certificate (PDF)
Product brochure: Download the MFE Series brochure (PDF, 736 KB). Distributors and project buyers can request the full LVD and EMC test reports and the English or Polish user manual.
Yes, if the existing duct is Ø100 mm or Ø120 mm, the two standard sizes. The spigot slides into the duct, the housing is fixed with four screws, and an electrician connects it to the 220–240 V supply. No enlarging of the opening is needed.
A good starting point is 60% to 70% RH, so the fan starts during a shower and stops once the room has dried. A lower setting makes it start sooner and run longer. If it runs too often, turn the dial up.
No. After each cycle it drops to reduced speed and switches off automatically after 24 hours. With the S1 switch off, the fan simply stops when the timer period ends.
No. The fan is Class II, double insulated. It is wired with a 2- or 3-core cable according to the diagram in the manual.
Disconnect the power first. Release the glass front with the supplied key, remove the panel and impeller and rinse them under running water up to 60 °C. Keep water away from the motor and electronics and dry all parts before refitting.
A printed logo on the glass panel, the packaging design, private-label barcodes and the factory-set humidity and timer values. Tell us your market and quantities and we will confirm the minimum order.
As a global manufacturer of HVAC and ventilation equipment, KCVENTS is dedicated to providing flexible customization services and robust long-term supply chain warranty terms for contractors, brands, and wholesalers.
We support full private labeling (OEM) and custom housing finishes. Our ODM engineering covers custom chassis modifications, specialized airflow curves, and regional electrical standards (e.g., 110V/60Hz, 24V variable frequency).
For large-scale HVAC and green building deployments, we offer structured MOQ tiers, staged shipping contracts, and agile multi-batch delivery aligned with your construction timeline. Technical submittals and parameter validation are included.
Motors enjoy an extended warranty of up to 3 to 5 years, backed by a comprehensive 1-year full system warranty. Bulk orders are eligible for a dedicated percentage of maintenance spares along with 1-on-1 remote engineering support.
Reviews
There are no reviews yet.